The Rolex Forums   The Rolex Watch

ROLEXROLEXROLEXROLEXROLEXROLEXROLEXROLEXROLEXROLEXROLEXROLEX


Go Back   Rolex Forums - Rolex Forum > Rolex & Tudor Watch Topics > Rolex WatchTech

View Poll Results: Does your 32xx movement seem to be 100% ok?
Yes, no issues 1,059 69.72%
No, amplitude is low (below 200) but timekeeping is still fine 62 4.08%
No, amplitude is low (below 200) and timekeeping is off (>5 s/d) 398 26.20%
Voters: 1519. You may not vote on this poll

 
 
Thread Tools Display Modes
Prev Previous Post   Next Post Next
Old 24 January 2021, 01:42 AM   #1
HiBoost
"TRF" Member
 
HiBoost's Avatar
 
Join Date: Apr 2012
Location: USA
Posts: 1,528
32xx movement problem poll and data thread

We've got several other threads talking about this movement, but my goal here is to have a single source of real data, both the poll question - has your movement had an issue, yes/no - and actual timegrapher data to give us a feel for "normal" amplitudes. I didn't want to go overboard with poll options so I left it more yes/no. If you had an issue, but have sent it in to RSC and it seems to be better now, please mark this as having an issue as it still represents a problem data point in the field.

Please answer the poll even if/especially if you have not had any issues!

If you don't have any amplitude data but you are still having significant timekeeping issues, please choose the 3rd option as well.


Here is mine: Brand new 126613LB Sub, worn on and off for 2 weeks. Lift angle set to 53 degrees, Weishi 1000, 4 second period. Watch allowed to settle for 2 minutes after changing positions. Then monitored for another 3 minutes.

Full wind (75 winds)

DU: +2 to +3 s/d, 256-262 deg
CU: -3 to -6 s/d, 208-218 deg
DD: +2 to +4 s/d, 250-257 deg
CD: 0 to -2 s/d, 216-224 deg

For most of the full wind tests across all positions the beat error was 0.2ms.

24 hours later (not worn or moved)

DU: +1 to +3 s/d, 231-237 deg
CU: -5 to -9 s/d, 185-197 deg
DD: +1 to +4 s/d, 222-226 deg
CD: 0 to -9 s/d, 188-195 deg

For most of the 24 hour tests across all positions the beat error was 0.0ms.
HiBoost is offline   Reply With Quote
 


Currently Active Users Viewing This Thread: 25 (0 members and 25 guests)
 

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump

Wrist Aficionado

DavidSW Watches

Takuya Watches

OCWatches

Asset Appeal


*Banners Of The Month*
This space is provided to horological resources.





Copyright ©2004-2024, The Rolex Forums. All Rights Reserved.

ROLEXROLEXROLEXROLEXROLEXROLEXROLEXROLEXROLEXROLEXROLEXROLEX

Rolex is a registered trademark of ROLEX USA. The Rolex Forums is not affiliated with ROLEX USA in any way.